Flow P.O. 100
PROPERTIES & ADVANTAGES:
ü Minimum foam formation, reducing the cavitation phenomenon when lubricating smooth bearings.
ü Reduced tendency to form deposits, keeping the gears in an optimum state of cleanliness.
ü Excellent thermal stability, allowing temperature peaks in excess of 100 ºC to be attained.
ü Rapid water separation which prevents the arrival of humidity at metal surfaces.
ü Higher wear-and-tear, anti-rust and anti-corrosion capacity.
ü Reduces power losses owing to friction, ensuring optimum performance and silent operation.
ü Its excellent Extreme Pressure properties make it suitable for usage on heavily loaded elements.
APPLICATIONS:
ü Guillotines (Polar, Wholemberg, etc.), Folders (Jagenberg, Bremer etc.), mechanical elements in Roland, Heidelberg, König Bauer, Wifag, Chambon machines etc.
ü Gear, reducer systems, smooth bearings, guides and rollers where a lubricant is required with EP properties.
ü Lubrication of elements with sliding loads and/or shock loading.
SPECIFICATIONS / QUALITY LEVEL:
| 
 DIN 51517 Parte 3 CLP  | 
 FIVES CINCINNATI P-76 (ISO-100)/ P-77 (ISO-150)/ P-74 (ISO220)  | 
| 
 US STEEL 224  | 
 AGMA 9005-D94 EP  | 
| 
 ISO 12925-1 e ISO 6743/6: CKC/CKD  | 
 DAVID BROWN S1.53.101-E  | 
TECHNICAL DATA:
| 
 PHYSICOCHEMICAL CHARACTERISTICS  | 
 STANDARD  | 
 VALUE  | 
||
| 
 ISO Grade  | 
 ISO 3448  | 
 100  | 
 150  | 
 220  | 
| 
 Viscosity at 40 ºC, Typical (cSt)  | 
 ASTM D-445  | 
 90-110  | 
 135-165  | 
 198-242  | 
| 
 Viscosity index  | 
 ASTM D-2270  | 
 95  | 
 95  | 
 95  | 
| 
 Density at 15 ºC, Typical (kg/l)  | 
 ASTM D-1298  | 
 0.880  | 
 0.890  | 
 0.900  | 
| 
 Pour point (ºC), max.  | 
 ASTM D-97  | 
 -20  | 
 -20  | 
 -15  | 
| 
 Flash point COC, min. (ºC)  | 
 ASTM D-92  | 
 230  | 
 230  | 
 250  | 
| 
 Copper corrosion (3h, 100 ºC), max.  | 
 ASTM D-130  | 
 1b  | 
 1b  | 
 1b  | 
| 
 FZG, Stage  | 
 DIN 51354/2  | 
 13  | 
 13  | 
 13  | 
| 
 TIMKEN load (lb)  | 
 ASTM D-2782  | 
 75  | 
 75  | 
 75  | 
| 
 4-ball EP test, welding load (kg)  | 
 IP-239  | 
 250  | 
 250  | 
 250  | 
| 
 4-ball wear test, scar (mm)  | 
 ASTM D-4172  | 
 ≤ 0.4  | 
 ≤ 0.4  | 
 ≤ 0.4  |