OLIPES Proactive Maintenance Plan
OLIPES will help you implementing a Proactive Maintenance Plan and establishing Absolute Alarms and Necessary Statistics. To do this
it relies on the experience of its highly qualified technical staff, on accumulated statistics and on the support of the main lubrication
analysis laboratories with whom it collaborates on a global level.
For the Program to be successful, proper selection of the systems or components to be monitored is essential, as is correct
establishment of limits and clean-up goals.
CONDITION TO Wear level on Lubricant
BE ANALYZED machinery contamination level Physicochemical characteristics of lubricant Additives remaining
ICP, Plasma (ASTM D 5185), PQ ICP (ASTM D 5185), FTIR, KF, TAN, Acid Number VISCOSITY ICP (ASTM D 5185), Metal
TESTS INSOLUBLES
Index,Wear Index (PE-5024-AI) Crakle Test (ASTM D 664), IR (PE-5008-AI) (ASTM D 445 - ASTM D 2270) additives (P,Zn,Ca,Mg,Li,S)
Wear particles (ppm): Determination of Level of oil oxidation Viscosity variation Dirt level of oil Remaining life of oil
CHECKS Al,Cu,Cr, Sn,Fe, Pb, etc. contamination by and estimation of its compared to (sewage). by concentration of
Bigger ferrous presence of water-Glycol, service life (additive original oil. its additives:
wear particles. concentration and nature reserve). S, Ca, P, etc.
thereof.
Contents outside of the Contamination by
indicated limits: wear freshwater/seawater A high level of Possible causes: Possible causes:
GEARS on gears or bearings by by condensation with oxidation could thickening of oil by oxidation of oil, Reserve of extreme
contamination, overload, a refrigerant. Risk of cause acidic oxidation, erroneous contamination by pressure (EP) additives.
misalignments, etc. premature corrosion and corrosion. replacements. solids.
Foreseeable breakdowns. wear on bearings and
gears.
A high content indicates:
wear on pumps, valves, Contamination by
and other components freshwater/seawater A high level of Possible causes: Possible causes:
HYDRULICS by contamination, high by condensation with oxidation could thickening of oil by oxidation of oil, Reserve of antiwear (AW)
pressure changes in the a refrigerant. Risk of cause acidic oxidation, erroneous contamination by additive.
bearings, etc. Associated premature corrosion and corrosion. replacements. solids.
symptoms: loss of yield. wear on pumps.
Sampling frequency recommended for auxiliary equipment:
Hydraulic systems, reducers, compressors, and thermal circuits: 6 months.
If you would like more information on implementing our OLIPES PROACTIVE MAINTENANCE PLAN:
Customer Service:
Technical Assistance Service: for calls from within Spain: (+34) 918 765 244 Ext. 206
sat@olipes.com
for calls from outside Spain: (+34) 918 765 603
1